1.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.05.31.20118315

ABSTRACT

We used a new strategy to screen cytokines associated with SARS-CoV-2 infection. Cytokines that can classify populations in different states of SARS-CoV-2 infection were first screened in cross-sectional serum samples from 184 subjects by 2 statistical analyses. The resultant cytokines were then analyzed for their interrelationships and fluctuating features in sequential samples from 38 COVID-19 patients. Three cytokines, M-CSF, IL-8 and SCF, which were clustered into 3 different correlation groups and had relatively small fluctuations during SARS-CoV-2 infection, were selected for the construction of a multiclass classification model. This model discriminated healthy individuals and asymptomatic and nonsevere patients with accuracy of 77.4% but was not successful in classifying severe patients. Further searching led to a single cytokine, hepatocyte growth factor (HGF), which classified severe from nonsevere COVID-19 patients with a sensitivity of 84.6% and a specificity of 97.9% under a cutoff value of 1128 pg/ml. The level of this cytokine did not increase in nonsevere patients but was significantly elevated in severe patients. Considering its potent antiinflammatory function, we suggest that HGF might be a new candidate therapy for critical COVID-19. In addition, our new strategy provides not only a rational and effective way to focus on certain cytokine biomarkers for infectious diseases but also a new opportunity to probe the modulation of cytokines in the immune response.


Subject(s)
Communicable Diseases , COVID-19
2.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.04.27.20074849

ABSTRACT

BackgroundThe purpose of current study is to evaluate the analytical performance of seven kits for detecting IgM/IgG antibody of corona virus (2019-nCoV) by using four chemiluminescence immunoassay systems. Methods50 patients diagnosed with 2019-nCoV infection and 130 controls without corona virus infection from the General Hospital of Chongqing were enrolled in current retrospective study. Four chemiluminescence immunoassay systems including seven IgM/IgG antibody detection Kits for 2019-nCoV (A_IgM, A_IgG, B_IgM, B_IgG, C_IgM, C_IgG, D_Ab) were employed to detecting antibody concentration. Chi-square test, receiver operating characteristic (ROC) curve and Youdens index were demonstrated to verify the cutoff value of each detection system. ResultsThe repeatability verification results of the A, B, C, and D system are all qualified. D-Ab performances best (92% sensitivity and 99.23% specificity), and B_IgM worse than other systems. Except for the system of A_IgM and C_IgG, the optimal diagnostic thresholds and cutoff value of other kits from recommendations are inconsistent with each other. B_IgM got the worst AUC and C_IgG had the best diagnostic accuracy. More importantly, B_IgG system have the highest false positive rate for testing patients with AIDS, tumor and pregnant. A_IgM system test showed highest false positive rates among elder over 90 years old. ConclusionsSystems for CoVID-2019 IgM/IgG antibody test performance difference. Serum diagnosis kit of D-Ab is the most reliable detecting system for 2019-nCoV antibody, which can be used as an alternative method for nucleic acid testing.


Subject(s)
COVID-19
3.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.03.18.20038018

ABSTRACT

Background We aim to investigate the profile of acute antibody response in COVID-19 patients, and provide proposals for the usage of antibody test in clinical practice. Methods A multi-center cross-section study (285 patients) and a single-center follow-up study (63 patients) were performed to investigate the feature of acute antibody response to SARS-CoV-2. A cohort of 52 COVID-19 suspects and 64 close contacts were enrolled to evaluate the potentiality of the antibody test. Results The positive rate for IgG reached 100% around 20 days after symptoms onset. The median day of serocon-version for both lgG and IgM was 13 days after symptoms onset. Seroconversion of IgM occurred at the same time, or earlier, or later than that of IgG. IgG levels in 100% patients (19/19) entered a platform within 6 days after seroconversion. The criteria of IgG seroconversion and [≥] 4-fold increase in the IgG titers in sequential samples together diagnosed 82.9% (34/41) of the patients. Antibody test aided to confirm 4 patients with COVID-19 from 52 suspects who failed to be confirmed by RT-PCR and 7 patients from 148 close contacts with negative RT-PCR. Conclusion IgM and IgG should be detected simultaneously at the early phase of infection. The serological diagnosis criterion of seroconversion or [≥] 4-fold increase in the IgG titer is suitable for a majority of COVID-19 patients. Serologic test is helpful for the diagnosis of SARS-CoV-2 infection in suspects and close contacts.


Subject(s)
COVID-19
4.
Chongqing Medicine ; (36): E023-E023, 2020.
Article in Chinese | WPRIM (Western Pacific), WPRIM (Western Pacific) | ID: covidwho-6285

ABSTRACT

Objective To compare and analyse the detection performance of different 2019-new coronavirus (2019-nCoV) nucleic acid detection kits, in order to provide references for laboratory. Methods Six kinds of domestic reagents (A—F reagent) were selected for parallel detection of a series of samples from one patient in this hospital whose 2019-nCoV nucleic acid result was confirmed weakly positive. The samples were taken at three different times, the RNAs were extracted and amplified, and two parallel tests were performed each time by use of these six kits. The detection performance was compared according to the results of each kit. Results The three parallel test results (ORF1ab and N gene) of C and F reagents were positive, the results of D reagent showed the N gene was not detected, and the results of A, B, E reagents showed the ORF1ab gene was not detected sometimes. The reproducibility of in-batch detections by C reagent was the best, and the CT values of F reagents (N and ORF1ab), E reagents (ORF1ab) and A reagents (ORF1ab) showed changes in trend. Conclusion There are differences in the detection ability of six 2019-nCoV nucleic acid detection reagents for weakly positive samples, and the accuracy, sensitivity and reproducibility of some reagents are not good. There is an urgent need to further optimize and improve their performance in order to better meet the needs of large-scale screening.

5.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.02.22.20026617

ABSTRACT

A respiratory illness has been spreading rapidly in China, since its outbreak in Wuhan city, Hubei province in December 2019. The illness was caused by a novel coronavirus, named severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Clinical manifestations related to SARS-CoV-2 infection ranged from no symptom to fatal pneumonia. World Health Organization (WHO) named the diseases associated with SARS-CoV-2 infection as COVID-19. Real time RT-PCR is the only laboratory test available till now to confirm the infection. However, the accuracy of real time RT-PCR depends on many factors, including sampling location and of methods, quality of RNA extraction and training of operators etc. Variations in these factors might significantly lower the sensitivity of the detection. We developed a peptide-based luminescent immunoassay to detect IgG and IgM. Cut-off value of this assay was determined by the detection of 200 healthy sera and 167 sera from patients infected with other pathogens than SARS-CoV-2. To evaluate the performance of this assay, we detected IgG and IgM in the 276 sera from confirmed patients. The positive rate of IgG and IgM were 71.4% (197/276) and 57.2% (158/276) respectively. By combining with real time RT-PCR detection, this assay might help to enhance the accuracy of diagnosis of SARS-CoV-2 infection.


Subject(s)
COVID-19 , Pneumonia